Skip to main content

Arduino Library

The Electrochemical Gas Sensor Soldered library reads the board through its ATtiny404 bridge when you give it an address from 0x30 to 0x37. At any other address it skips the bridge and talks to the ADS1115 and LMP91000 directly. Include Electrochemical-Gas-Sensor-SOLDERED.h, create an ElectrochemicalGasSensor with the SENSOR_CO preset and the board's address (0x30 by default), call begin(), and read the concentration with getPPM().

Not installed yet? Follow Quick Start before using the functionality pages.

Functionality​

Each page starts with one library example and explains every function the example uses to get that result. Some examples use another cell's preset; their pages say where to put SENSOR_CO, the preset for this board's cell.