Quick Start
Connect the breakout over Qwiic, install the library, and print the NO2 concentration in ppm.
You program the controller connected to this breakout. The breakout itself is not flashed: its ATtiny404 runs factory firmware that the libraries talk to.
The board runs from 3.3 V only. It has no regulator, and the header and both
Qwiic connectors share one 3.3 V supply. Do not connect 5 V to 3V3 or to
any signal pin.
- Arduino
- MicroPython
1. Connect the breakout board
Plug a Qwiic cable into either Qwiic connector on the board and into the Qwiic connector on your controller. The cable carries 3.3 V, ground and I2C, so it powers the board and connects it in one step. Leave the three ADDRESS switches as they ship: the example talks to the board at its default address, 0x30.
| NULA DeepSleep | Soldered Electrochemical NO2 Gas Sensor Breakout (Qwiic) |
|---|---|
| Qwiic connector | Qwiic connector |
Without Qwiic: breadboard wiring
The board is not made to plug into a breadboard. Solder the included header
pins and connect the four pins at the left end of the top header to your
controller's 3.3 V supply, ground and I2C pins with jumper wires. SDA1 and
SCL1 are the same bus as the Qwiic connectors.
| NULA DeepSleep | Soldered Electrochemical NO2 Gas Sensor Breakout (Qwiic) |
|---|---|
| GND | GND |
| 3V3 | 3V3 |
| IO8 | SDA1 |
| IO9 | SCL1 |
Leave SDA2 and SCL2 unconnected: they are the board's internal bus between
the ATtiny404, the LMP91000 and the ADS1115.
2. Install the library
Install Electrochemical Gas Sensor Soldered from its GitHub repository.
🔗Soldered Electrochemical Gas Sensor Arduino library
Verified Arduino library at commit c4df54b
Tip: downloading from GitHub. On the library's GitHub page, click the green Code button and choose Download ZIP, then add it in Arduino IDE with Sketch → Include Library → Add .ZIP Library....
3. Run the first example
Open bridgeBoard from the library's examples. It creates the sensor at address 0x30, which tells the library to talk to the board's ATtiny404, then prints a reading every 2.5 seconds.
The example creates the sensor with the carbon monoxide preset, SENSOR_CO.
Change SENSOR_CO
to SENSOR_NO2 before you upload it: SENSOR_NO2 is the library's preset
for the SGX-4NO2 cell on this board, and the ppm calculation uses its values.
/**
**************************************************
*
* @file bridgeBoard.ino
* @brief See how to init a sensor on the new ATtiny404 bridge board revision,
*
* To successfully run the sketch:
* - Set the desired address using the jumpers on the back of the board
* (address = 0x30 + jumper offset, giving a range of 0x30-0x37)
* - Run the sketch and open serial monitor at 115200 baud!
*
* Note: on this board revision, LMPEN is hardwired to GND, so there's
* no configPin argument to pass - the constructor's third argument
* is ignored whenever the address falls in the bridge range (0x30-0x37).
*
*
* @authors @ soldered.com
***************************************************/
// Include the required library
#include "Electrochemical-Gas-Sensor-SOLDERED.h"
// Any additional boards on the same bus just need a different jumper setting
// (0x30-0x37), same as twoSensors.ino does for legacy boards with 0x49/0x4A/0x4B.
ElectrochemicalGasSensor sensor(SENSOR_CO, 0x30);
void setup()
{
Serial.begin(115200); // For debugging
// Init the breakout
if (!sensor.begin())
{
// Can't init? Notify the user and go to infinite loop
Serial.println("ERROR: Can't init the sensor! Check connections and jumper address!");
while (true)
delay(100);
}
Serial.println("Sensor initialized successfully!");
}
void loop()
{
// Make the reading
double reading = sensor.getPPM();
// If PPB is more relevant for your sensor, you can use:
// double reading = sensor.getPPB();
// Print the reading with 5 digits of precision
Serial.print("Sensor reading: ");
Serial.print(reading, 5);
Serial.println(" PPM");
// Wait a bit before reading again
delay(2500);
}
The comment at the top of the example says LMPEN is hardwired to GND. On this
board LMPEN is the LMP91000's enable input and is also wired to the ATtiny404,
as Hardware Details
shows. Either way you connect nothing to it: at addresses 0x30 to 0x37 the
library does not use the constructor's third argument.
4. Check the result
Open the Serial Monitor at 115200 baud. When the board answers, the sketch prints:
Sensor initialized successfully!
Sensor reading: 0.01439 PPM
Sensor reading: 0.01405 PPM
Sensor reading: 0.01371 PPM
Sensor reading: 0.01442 PPM
A new Sensor reading: line follows every 2.5 seconds, with the NO2
concentration in ppm to five decimals. The library never
reports a negative concentration: a result below zero is shown as 0.
If you see ERROR: Can't init the sensor! Check connections and jumper address!
instead, the board did not answer at 0x30.
5. If it does not work
Continue with Troubleshooting and retry this smallest example after each change.
1. Connect the breakout board
Plug a Qwiic cable into either Qwiic connector on the board and into the Qwiic connector on your controller. The cable carries 3.3 V, ground and I2C, so it powers the board and connects it in one step. Leave the three ADDRESS switches as they ship: the example talks to the board at its default address, 0x30.
| NULA DeepSleep | Soldered Electrochemical NO2 Gas Sensor Breakout (Qwiic) |
|---|---|
| Qwiic connector | Qwiic connector |
The example sets SDA to pin 21 and SCL to pin 22. On the NULA DeepSleep, change them to 8 (SDA) and 9 (SCL), the board's I2C pins shown in the diagram.
Without Qwiic: breadboard wiring
The board is not made to plug into a breadboard. Solder the included header
pins and connect the four pins at the left end of the top header to your
controller with jumper wires. The example opens I2C bus 0 with SCL on pin 22
and SDA on pin 21; change those numbers in the example if you wire other pins.
| NULA DeepSleep | Soldered Electrochemical NO2 Gas Sensor Breakout (Qwiic) |
|---|---|
| GND | GND |
| 3V3 | 3V3 |
| IO8 | SDA1 |
| IO9 | SCL1 |
The example sets SDA to pin 21 and SCL to pin 22. On the NULA DeepSleep, change them to 8 (SDA) and 9 (SCL), the board's I2C pins shown in the diagram.
Leave SDA2 and SCL2 unconnected: they are the board's internal bus between
the ATtiny404, the LMP91000 and the ADS1115.
2. Install the module
After installing the mpremote package, install the library on your board using the following command:
mpremote mip install github:SolderedElectronics/Soldered-ElectrochemicalGasSensor-MicroPython-Library
Or, if you're running a Windows OS:
python -m mpremote mip install github:SolderedElectronics/Soldered-ElectrochemicalGasSensor-MicroPython-Library
🔗Soldered Electrochemical Gas Sensor MicroPython library
Verified MicroPython module at commit 623e1e6
Tip: downloading from GitHub. Without mpremote, open the module's .py
file on GitHub and click Download raw file, then open it in Thonny and use
File → Save as... → MicroPython device to copy it onto the board. This
library needs all three files: ElectrochemicalGasSensor.py, ads1115.py and
lmp91000.py.
3. Run the first example
This is the module's electrochemical-bridgeBoard.py example. It creates the
sensor at address 0x30, which tells the module to talk to the board's ATtiny404,
then prints a reading every 2.5 seconds.
The example creates the sensor with the ozone preset, SENSOR_O3. Change
SENSOR_O3 to SENSOR_NO2 in both places, the import line and the line
that creates the sensor: SENSOR_NO2 is the module's preset for the SGX-4NO2
cell on this board.
# FILE: electrochemical-bridgeBoard.py
# AUTHOR: Fran Fodor @ Soldered
# BRIEF: Single sensor PPM reading example for the ATtiny404 bridge board revision,
# which allows daisy-chaining multiple boards on one I2C bus.
# LAST UPDATED: 2026-07-23
# Connecting diagram:
#
# Qwiic------------------------>Qwiic
#
# Note: on this board revision, LMPEN is hardwired to GND, so there's no
# config_pin to set - it's ignored whenever adc_addr falls in the bridge
# range (0x30-0x37). Set the desired address using the jumpers on the back
# of the board before powering it on.
from machine import I2C, Pin
import time
from ElectrochemicalGasSensor import ElectrochemicalGasSensor, SENSOR_O3
# Initialize I2C
i2c = I2C(0, scl=Pin(22), sda=Pin(21))
# (address = 0x30 + jumper offset, giving a range of 0x30-0x37).
# Any additional boards on the same bus just need a different jumper
# setting, same as twoSensors.py does for legacy boards with 0x49/0x4A/0x4B.
sensor = ElectrochemicalGasSensor(SENSOR_O3, i2c, adc_addr=0x30)
# -------------------------------------------------------------------------
# Setup
# -------------------------------------------------------------------------
print("Electrochemical Gas Sensor - ATtiny Bridge Board Example")
if not sensor.begin():
print("ERROR: Can't init the sensor! Check connections and jumper address!")
while True:
time.sleep_ms(100)
print("Sensor initialized successfully!")
# -------------------------------------------------------------------------
# Main loop
# -------------------------------------------------------------------------
while True:
reading = sensor.getPPM()
# If PPB is more relevant for your sensor, use:
# reading = sensor.getPPB()
print("Sensor reading: {:.5f} PPM".format(reading))
time.sleep_ms(2500)
🔗Open the complete example
Examples/electrochemical-bridgeBoard.py at commit 623e1e6
The comment at the top of the example says LMPEN is hardwired to GND. On this
board LMPEN is the LMP91000's enable input and is also wired to the ATtiny404,
as Hardware Details
shows. Either way you connect nothing to it: at adc_addr 0x30 to 0x37 the
module does not use config_pin.
4. Check the result
When the board answers, the shell shows:
Electrochemical Gas Sensor - ATtiny Bridge Board Example
Sensor initialized successfully!
Sensor reading: 0.01443 PPM
Sensor reading: 0.01407 PPM
Sensor reading: 0.01431 PPM
Sensor reading: 0.01423 PPM
A new Sensor reading: line follows every 2.5 seconds, with the NO2
concentration in ppm to five decimals. A result below
zero is shown as 0.
If you see ERROR: Can't init the sensor! Check connections and jumper address!
instead, the board did not answer at 0x30.
5. If it does not work